Design and fabrication of long focal length microlens arrays
Abstract(#br)In this paper, we present microlens arrays (MLA) with long focal length (in millimeter range) based on thermal reflow process. The focal length of microlens is usually in the same order of lens diameter or several hundred microns. To extend focal length, we made a photoresist (SU-8) MLA covered by a Polydimethylsiloxane (PDMS) film on a glass substrate. Because the refractive index difference between PDMS and photoresist interface is lower than that of air and MLA interface, light is less bended when passing through MLA and is focused at longer distance.