Inter-laboratory validation of a thin film microextraction technique for determination of pesticides in surface water samples

ty10086 提交于 周四, 08/26/2021 - 13:23
文章英文标题
Inter-laboratory validation of a thin film microextraction technique for determination of pesticides in surface water samples
正文
Abstract(#br)The primary goal of the present study is the inter-laboratory evaluation of a thin film microextraction (TFME) technique to be used as an alternative approach to liquid-liquid extraction (LLE). Polydimethylsiloxane/divinylbenzene (PDMS/DVB) and PDMS/DVB-carbon mesh supported membranes were used for the extraction of 23 targeted pesticides, while a thermal desorption unit (TDU) was employed to transfer these analytes to a GC/MS instrument for separation and detection. After optimization of the most critical parameters, both membranes were capable of achieving limits of detection (LOD) in the low ng L −1 range while demonstrating excellent robustness, withstanding up to 100 extractions/desorption cycles. Furthermore, limits of quantification (LOQ) between 0.025 and 0.50 μg L −1 were achieved for the 23 compounds selected from several classes of pesticides with a wide range of polarities. A wide linear range of 0.025–10.0 μg L −1 with strong correlation to response (R 2 \u003e 0.99) was attained for most of the studied analytes. Both membranes showed good accuracy and repeatability at three levels of concentration. Moreover, the method was also validated through blind split analyses of 18 surface water samples, collected within 3 months, using TFME at the University of Waterloo and LLE at Maxxam Analytics (Mississauga, ON) which is an accredited commercial analytical laboratory. Good agreement between the two methods was achieved with accuracy values ranging from 70 to 130%, for the majority of analytes in the samples collected. At the concentration levels investigated, 90% of the analytes were quantifiable by TFME, whereas only 53% of the compounds were reportable using the LLE method particularly at concentrations lower than 1 μg L −1 . The comparison of TFME and LLE from several analytical aspects demonstrated that the novel TFME method gave similar accuracy to LLE, while providing additional advantages including higher sensitivity, lower sample volume, thus reduced waste production, and faster analytical throughput. Given the sensitivity, simplicity, low cost, accuracy, greenness and relatively fast procedure of TFME, it shows great potential for adoption in analytical laboratories as an alternative to LLE.
文章内容(英文)
Abstract(#br)The primary goal of the present study is the inter-laboratory evaluation of a thin film microextraction (TFME) technique to be used as an alternative approach to liquid-liquid extraction (LLE). Polydimethylsiloxane/divinylbenzene (PDMS/DVB) and PDMS/DVB-carbon mesh supported membranes were used for the extraction of 23 targeted pesticides, while a thermal desorption unit (TDU) was employed to transfer these analytes to a GC/MS instrument for separation and detection. After optimization of the most critical parameters, both membranes were capable of achieving limits of detection (LOD) in the low ng L −1 range while demonstrating excellent robustness, withstanding up to 100 extractions/desorption cycles. Furthermore, limits of quantification (LOQ) between 0.025 and 0.50 μg L −1 were achieved for the 23 compounds selected from several classes of pesticides with a wide range of polarities. A wide linear range of 0.025–10.0 μg L −1 with strong correlation to response (R 2 \u003e 0.99) was attained for most of the studied analytes. Both membranes showed good accuracy and repeatability at three levels of concentration. Moreover, the method was also validated through blind split analyses of 18 surface water samples, collected within 3 months, using TFME at the University of Waterloo and LLE at Maxxam Analytics (Mississauga, ON) which is an accredited commercial analytical laboratory. Good agreement between the two methods was achieved with accuracy values ranging from 70 to 130%, for the majority of analytes in the samples collected. At the concentration levels investigated, 90% of the analytes were quantifiable by TFME, whereas only 53% of the compounds were reportable using the LLE method particularly at concentrations lower than 1 μg L −1 . The comparison of TFME and LLE from several analytical aspects demonstrated that the novel TFME method gave similar accuracy to LLE, while providing additional advantages including higher sensitivity, lower sample volume, thus reduced waste production, and faster analytical throughput. Given the sensitivity, simplicity, low cost, accuracy, greenness and relatively fast procedure of TFME, it shows great potential for adoption in analytical laboratories as an alternative to LLE.
来源出处
Journal|[J]Analytica Chimica Acta2017.
DOI
https://doi.org/10.1016/j.aca.2017.02.014

PDMS臻品推荐

PDMS-微流控基质材料-PDMS/道康宁SYLGARD184-聚二甲基硅氧烷/0.5KG(组)

产品说明书PDF自助在线看:http://www.pdmshub.com/sih

信息更新:

美国总工厂生产的0.5KG原始包装的PDMS延期至2021年9月16日后才能交货,默认我们将发国内库存的进口分装产品(02085925-0.5KG);另受制于有机硅大幅涨价潮影响,2021年9月1日后将上调销售价格,另行通知。Dow Corning=道康宁=Dow SiL=陶氏,都是同一家公司。 2021.09.01更新

美国总工厂生产的0.5KG包装的PDMS恢复正常进口,合法正规,质量金标准,欢迎订购使用。并承诺从我司购买的皆为原厂包装,100%未开封,附带技术手册,非国产灌装仿制、非分装、非仿冒外包装产品,可以放心使用。大量订购更有优惠。2021.04.01更新

备注:由于dowsil与道康宁公司合并,美国总工厂生产的PDMS,价格涨幅高达1倍之多,因针对科研用户使用,特备货规格0.5KG。如果您需要美国总工厂原厂生产的大规格包装的预定,可以与QQ 11366508联系给予报价/货期。2021.05更新

此链接为PDMS-微流控芯片/PDMS/道康宁SYLGARD184/小桶0.5KG装的链接。

一般性的产品性能参数表参考以下小桶装的参数:

微流控芯片/PDMS/道康宁SYLGARD184;微流控芯片/PDMS/道康宁SYLGARD184;微流控芯片/PDMS/道康宁SYLGARD184;

品牌型号:道康宁SYLGARD184

包装规格:0.5KG/罐[含有45.4g固化剂,总重量为0.5KG]

产品颜色:保质期限:36个月

存放环境说明:室温,阴凉处保存

备注说明:

美国道康宁道康宁SYLGARD 184硅橡胶是由液体组分组成的双组分套件产品,包括基本组分与固化剂。基本组分与固化剂按10:1重量比完全混合,中等粘度混合液的稠度与SAE 40机油相似。无论厚薄,混合液将固化成为具有韧性的透明弹性体,最适用于电子/电气方面的封装与灌封应用。 道康宁SYLGARD 184硅橡胶在25~150℃的温度范围内固化,无放热现象,无需二次固化。固化过程完成后,可立即在-55~200℃的温度范围内使用。 产品特性:低毒性,在常规的工业操作中,无特别的注意事项; 无溶剂或固化副产物, 固化时不放热;无需特殊的通风条件,不会产生腐蚀;固化时,收缩量小; 固化后, 透明具有弹性;抗震与减缓机械震动;振动的传递性能小;元件可裸视检查与易修补性; 环保性能;低吸水性,良好的耐辐射性能;高真空状态下的低漏气性; 优异的电性能;较大温度范围内的稳定性, 抗解聚;在-55~200℃范围内,甚至在密闭状态下保持弹性与柔韧性,性能稳定; 阻燃性,UL可燃性分级为94 V-1,温度等级:130℃ 产品用途: 道康宁SYLGARD 184硅橡胶在电气/电子的封装与灌封方面有广泛的应用。