污染水体中PAHs超灵敏测定方法VA-TV-SPME法的设计与优化

ty10086 提交于 周三, 08/25/2021 - 17:18
文章英文标题
Design and optimization of the VA-TV-SPME method for ultrasensitive determination of the PAHs in polluted water
正文
摘要\n本文描述了如何在真空条件下对样品进行全汽化,发展出一种新颖可靠的常规固相微萃取( SPME )采样的替代方法。SPME取样由平衡过程的两个阶段组成,分别发生在样品/顶空和顶空/纤维涂层之间。在全蒸发SPME ( TV-SPME )策略中,省略了第一阶段,分析物直接在顶空和纤维涂层之间进行分区。本研究采用一种聚二甲基硅氧烷( PDMS )包复的SPME纤维,通过从水介质中萃取PAHs来实现TV-SPME策略。对最重要的变量进行了考察和优化。在萃取温度55℃、汽化时间25 min、进样量100μL条件下得到最佳条件。为了在较短的时间内获得较高的灵敏度,将TV - SPME装置与VA - SPME系统耦合,使得萃取温度和时间比传统的TV - SPME方法要低得多。在最佳实验条件下,线性范围为0.015 ~ 2μg mL-1 ( R2 \u003e 0.996 )。检出限( LODs )在0.3 ~ 5 ng m L-1范围内,相对标准偏差( RSD,n = 6 )为6.1 ~ 7.5 %。开发的真空辅助全蒸发SPME ( VA-TV-SPME )技术,与GC- FID联用,成功用于河流水样中多环芳烃( PAHs )的测定。所得数据与采用经过验证的核准方法取得的数据在统计上一致。
文章内容(英文)
Abstract(#br)This paper describes how a novel and reliable alternative approach was developed for conventional solid-phase microextraction (SPME) sampling by total-vaporization of a sample under vacuum conditions. SPME sampling consists two stages of the equilibrium process, which take place between the sample/headspace and the headspace/fiber coating. In the total-vaporization SPME (TV-SPME) strategy, the first stage is omitted and analytes are directly partitioned between the headspace and fiber coating. In this research, the TV-SPME strategy was implemented by the extraction of PAHs from aqueous media, using a polydimethylsiloxane (PDMS) coated SPME fiber. The most important variables were investigated and optimized. Optimal conditions were obtained at an extraction temperature of 55 °C, a vaporization time of 25 min, and a sample volume of 100 μL. To achieve higher sensitivities in shorter times, the TV-SPME setup was coupled with the VA-SPME system, which resulted in a much lower extraction temperature and time, in comparison with the conventional TV-SPME method. Under optimal experimental conditions, the calibration curves were linear across the area of 0.015–2 μg mL −1 ( R 2 \u003e 0.996). The limits of detection (LODs) were obtained in the range of 0.3–5 ng mL −1 , and the relative standard deviations (RSDs, n = 6) were 6.1–7.5%. The developed vacuum-assisted total-vaporization SPME (VA-TV-SPME) technique, was coupled with GC-FID and successfully utilized for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples. The data obtained was statistically in accordance with that achieved employing a validated approved method.
来源出处
Journal|[J]TalantaVolume 212, 2020.
DOI
https://doi.org/10.1016/j.talanta.2020.120809

PDMS臻品推荐

PDMS-微流控基质材料-PDMS/道康宁SYLGARD184-聚二甲基硅氧烷/0.5KG(组)

产品说明书PDF自助在线看:http://www.pdmshub.com/sih

信息更新:

美国总工厂生产的0.5KG原始包装的PDMS延期至2021年9月16日后才能交货,默认我们将发国内库存的进口分装产品(02085925-0.5KG);另受制于有机硅大幅涨价潮影响,2021年9月1日后将上调销售价格,另行通知。Dow Corning=道康宁=Dow SiL=陶氏,都是同一家公司。 2021.09.01更新

美国总工厂生产的0.5KG包装的PDMS恢复正常进口,合法正规,质量金标准,欢迎订购使用。并承诺从我司购买的皆为原厂包装,100%未开封,附带技术手册,非国产灌装仿制、非分装、非仿冒外包装产品,可以放心使用。大量订购更有优惠。2021.04.01更新

备注:由于dowsil与道康宁公司合并,美国总工厂生产的PDMS,价格涨幅高达1倍之多,因针对科研用户使用,特备货规格0.5KG。如果您需要美国总工厂原厂生产的大规格包装的预定,可以与QQ 11366508联系给予报价/货期。2021.05更新

此链接为PDMS-微流控芯片/PDMS/道康宁SYLGARD184/小桶0.5KG装的链接。

一般性的产品性能参数表参考以下小桶装的参数:

微流控芯片/PDMS/道康宁SYLGARD184;微流控芯片/PDMS/道康宁SYLGARD184;微流控芯片/PDMS/道康宁SYLGARD184;

品牌型号:道康宁SYLGARD184

包装规格:0.5KG/罐[含有45.4g固化剂,总重量为0.5KG]

产品颜色:保质期限:36个月

存放环境说明:室温,阴凉处保存

备注说明:

美国道康宁道康宁SYLGARD 184硅橡胶是由液体组分组成的双组分套件产品,包括基本组分与固化剂。基本组分与固化剂按10:1重量比完全混合,中等粘度混合液的稠度与SAE 40机油相似。无论厚薄,混合液将固化成为具有韧性的透明弹性体,最适用于电子/电气方面的封装与灌封应用。 道康宁SYLGARD 184硅橡胶在25~150℃的温度范围内固化,无放热现象,无需二次固化。固化过程完成后,可立即在-55~200℃的温度范围内使用。 产品特性:低毒性,在常规的工业操作中,无特别的注意事项; 无溶剂或固化副产物, 固化时不放热;无需特殊的通风条件,不会产生腐蚀;固化时,收缩量小; 固化后, 透明具有弹性;抗震与减缓机械震动;振动的传递性能小;元件可裸视检查与易修补性; 环保性能;低吸水性,良好的耐辐射性能;高真空状态下的低漏气性; 优异的电性能;较大温度范围内的稳定性, 抗解聚;在-55~200℃范围内,甚至在密闭状态下保持弹性与柔韧性,性能稳定; 阻燃性,UL可燃性分级为94 V-1,温度等级:130℃ 产品用途: 道康宁SYLGARD 184硅橡胶在电气/电子的封装与灌封方面有广泛的应用。