Application of polypropylene tubes as single-use and low-cost sorptive extraction materials for the determination of benzodiazepines and zolpidem in water samples

ty10086 提交于 周四, 08/26/2021 - 13:31
文章英文标题
Application of polypropylene tubes as single-use and low-cost sorptive extraction materials for the determination of benzodiazepines and zolpidem in water samples
正文
Abstract(#br)This work presents a method for the simultaneous determination in water of 17 benzodiazepines (BZPs) and a related pharmaceutical (zolpidem) by extraction with low-cost polymeric sorbents followed by liquid chromatography-tandem mass spectrometry (LC–MS/MS). Different polymers were considered: polydimethylsiloxane (PDMS), polypropylene (PP), and polyethersulfone (PES), providing the second one (PP) higher responses. Hence, different operational parameters were considered and optimized using PP as polymeric material for the extraction: ionic strength (as NaCl addition), sample pH, sample volume, extraction time, amount of extractant phase, desorption solvent and desorption time. Under the optimized conditions, 70\u003cce:hsp sp=\"0.25\"/\u003emL of sample (pH\u003cce:hsp sp=\"0.25\"/\u003e9) with 30% (w/v) of NaCl was extracted with four PP tubes (10\u003cce:hsp sp=\"0.25\"/\u003emm, ≈\u003cce:hsp sp=\"0.10\"/\u003e1\u003cce:hsp sp=\"0.25\"/\u003emg each) during 14\u003cce:hsp sp=\"0.25\"/\u003eh at room temperature, the analytes eluted with 1\u003cce:hsp sp=\"0.25\"/\u003emL of acetone and the eluate concentrated to dryness, reconstituted in methanol and analyzed by LC–MS/MS. Under these conditions, extraction efficiencies ranged between 41 and 86%, leading to enrichment factors from 574 to 1204. Satisfactory trueness, expressed as relative recoveries, was obtained in the 87–117% range. LOQs ranged from 0.4 to 31\u003cce:hsp sp=\"0.25\"/\u003eng\u003cce:hsp sp=\"0.25\"/\u003eL −\u003cce:hsp sp=\"0.10\"/\u003e1 and from 2 to 94\u003cce:hsp sp=\"0.25\"/\u003eng\u003cce:hsp sp=\"0.25\"/\u003eL −\u003cce:hsp sp=\"0.10\"/\u003e1 for river and influent wastewater, respectively. None of the analytes were detected in river water while 6 of them were detected in wastewater samples in concentrations between 4 and 152\u003cce:hsp sp=\"0.25\"/\u003eng\u003cce:hsp sp=\"0.25\"/\u003eL −\u003cce:hsp sp=\"0.10\"/\u003e1 , being lorazepam and oxazepam the analytes detected at the highest concentration level. Thus, PP may become a good alternative to PDMS or PES for the extraction of basic analytes.
文章内容(英文)
Abstract(#br)This work presents a method for the simultaneous determination in water of 17 benzodiazepines (BZPs) and a related pharmaceutical (zolpidem) by extraction with low-cost polymeric sorbents followed by liquid chromatography-tandem mass spectrometry (LC–MS/MS). Different polymers were considered: polydimethylsiloxane (PDMS), polypropylene (PP), and polyethersulfone (PES), providing the second one (PP) higher responses. Hence, different operational parameters were considered and optimized using PP as polymeric material for the extraction: ionic strength (as NaCl addition), sample pH, sample volume, extraction time, amount of extractant phase, desorption solvent and desorption time. Under the optimized conditions, 70\u003cce:hsp sp=\"0.25\"/\u003emL of sample (pH\u003cce:hsp sp=\"0.25\"/\u003e9) with 30% (w/v) of NaCl was extracted with four PP tubes (10\u003cce:hsp sp=\"0.25\"/\u003emm, ≈\u003cce:hsp sp=\"0.10\"/\u003e1\u003cce:hsp sp=\"0.25\"/\u003emg each) during 14\u003cce:hsp sp=\"0.25\"/\u003eh at room temperature, the analytes eluted with 1\u003cce:hsp sp=\"0.25\"/\u003emL of acetone and the eluate concentrated to dryness, reconstituted in methanol and analyzed by LC–MS/MS. Under these conditions, extraction efficiencies ranged between 41 and 86%, leading to enrichment factors from 574 to 1204. Satisfactory trueness, expressed as relative recoveries, was obtained in the 87–117% range. LOQs ranged from 0.4 to 31\u003cce:hsp sp=\"0.25\"/\u003eng\u003cce:hsp sp=\"0.25\"/\u003eL −\u003cce:hsp sp=\"0.10\"/\u003e1 and from 2 to 94\u003cce:hsp sp=\"0.25\"/\u003eng\u003cce:hsp sp=\"0.25\"/\u003eL −\u003cce:hsp sp=\"0.10\"/\u003e1 for river and influent wastewater, respectively. None of the analytes were detected in river water while 6 of them were detected in wastewater samples in concentrations between 4 and 152\u003cce:hsp sp=\"0.25\"/\u003eng\u003cce:hsp sp=\"0.25\"/\u003eL −\u003cce:hsp sp=\"0.10\"/\u003e1 , being lorazepam and oxazepam the analytes detected at the highest concentration level. Thus, PP may become a good alternative to PDMS or PES for the extraction of basic analytes.
来源出处
Journal|[J]Microchemical JournalVolume 119, 2015. PP 58-65
DOI
https://doi.org/10.1016/j.microc.2014.10.011

PDMS臻品推荐

PDMS-微流控基质材料-PDMS/道康宁SYLGARD184-聚二甲基硅氧烷/0.5KG(组)

产品说明书PDF自助在线看:http://www.pdmshub.com/sih

信息更新:

美国总工厂生产的0.5KG原始包装的PDMS延期至2021年9月16日后才能交货,默认我们将发国内库存的进口分装产品(02085925-0.5KG);另受制于有机硅大幅涨价潮影响,2021年9月1日后将上调销售价格,另行通知。Dow Corning=道康宁=Dow SiL=陶氏,都是同一家公司。 2021.09.01更新

美国总工厂生产的0.5KG包装的PDMS恢复正常进口,合法正规,质量金标准,欢迎订购使用。并承诺从我司购买的皆为原厂包装,100%未开封,附带技术手册,非国产灌装仿制、非分装、非仿冒外包装产品,可以放心使用。大量订购更有优惠。2021.04.01更新

备注:由于dowsil与道康宁公司合并,美国总工厂生产的PDMS,价格涨幅高达1倍之多,因针对科研用户使用,特备货规格0.5KG。如果您需要美国总工厂原厂生产的大规格包装的预定,可以与QQ 11366508联系给予报价/货期。2021.05更新

此链接为PDMS-微流控芯片/PDMS/道康宁SYLGARD184/小桶0.5KG装的链接。

一般性的产品性能参数表参考以下小桶装的参数:

微流控芯片/PDMS/道康宁SYLGARD184;微流控芯片/PDMS/道康宁SYLGARD184;微流控芯片/PDMS/道康宁SYLGARD184;

品牌型号:道康宁SYLGARD184

包装规格:0.5KG/罐[含有45.4g固化剂,总重量为0.5KG]

产品颜色:保质期限:36个月

存放环境说明:室温,阴凉处保存

备注说明:

美国道康宁道康宁SYLGARD 184硅橡胶是由液体组分组成的双组分套件产品,包括基本组分与固化剂。基本组分与固化剂按10:1重量比完全混合,中等粘度混合液的稠度与SAE 40机油相似。无论厚薄,混合液将固化成为具有韧性的透明弹性体,最适用于电子/电气方面的封装与灌封应用。 道康宁SYLGARD 184硅橡胶在25~150℃的温度范围内固化,无放热现象,无需二次固化。固化过程完成后,可立即在-55~200℃的温度范围内使用。 产品特性:低毒性,在常规的工业操作中,无特别的注意事项; 无溶剂或固化副产物, 固化时不放热;无需特殊的通风条件,不会产生腐蚀;固化时,收缩量小; 固化后, 透明具有弹性;抗震与减缓机械震动;振动的传递性能小;元件可裸视检查与易修补性; 环保性能;低吸水性,良好的耐辐射性能;高真空状态下的低漏气性; 优异的电性能;较大温度范围内的稳定性, 抗解聚;在-55~200℃范围内,甚至在密闭状态下保持弹性与柔韧性,性能稳定; 阻燃性,UL可燃性分级为94 V-1,温度等级:130℃ 产品用途: 道康宁SYLGARD 184硅橡胶在电气/电子的封装与灌封方面有广泛的应用。